Sicoma batching plant thunderstorm weather protection
The sicoma batching plant adopt SICOMA concrete mixer as the mixing host with high efficiency and stable running. The recent thundery weather is particularly prevalent. In some places, even more intense rainfall has continued and floods have already occurred in many areas. So what precautions should be taken to sicoma batching plant in such thunderstorms? We will analyze it from 5 aspects.
1. In the thunderstorm weather, the concrete batching plant should stop production and disconnect the power supply .
2. Set up over-voltage protectors to protect these mechanical micro-electronic control devices with extremely high control sensitivity from inductive surge surge voltage invasion and damage.
3. The main grounding terminal of the batching plant, the grounding terminal of the cement chamber, the grounding terminal on the main control room leg and the grounding wire connected to the grounding electrode. The conductors, flat steels, or other bare conductors that meet the corresponding requirements of the grounding wire.
4. The fixed points of the lightning rod on the batching plant should be insulated to prevent lightning from passing through the main body of the concrete batch plant, and the height of the lightning rod should be higher than the highest point of the sicoma batching plant.
5. Set up more lightning rods to achieve an effective radius of protection, to ensure that all lightning strikes flow to the earth through the lightning conductor to prevent direct lightning strikes.
1. In the thunderstorm weather, the concrete batching plant should stop production and disconnect the power supply .
2. Set up over-voltage protectors to protect these mechanical micro-electronic control devices with extremely high control sensitivity from inductive surge surge voltage invasion and damage.
3. The main grounding terminal of the batching plant, the grounding terminal of the cement chamber, the grounding terminal on the main control room leg and the grounding wire connected to the grounding electrode. The conductors, flat steels, or other bare conductors that meet the corresponding requirements of the grounding wire.
4. The fixed points of the lightning rod on the batching plant should be insulated to prevent lightning from passing through the main body of the concrete batch plant, and the height of the lightning rod should be higher than the highest point of the sicoma batching plant.
5. Set up more lightning rods to achieve an effective radius of protection, to ensure that all lightning strikes flow to the earth through the lightning conductor to prevent direct lightning strikes.